Custom Schedule
A Custom Schedule automation runs a single action at a specific time each day — on the days and months you choose. It’s the simplest way to automate your Powerwall’s behavior on a predictable schedule.
What it does
Section titled “What it does”When a Custom Schedule automation fires, it can:
- Switch operational mode — change your Powerwall between self-consumption and autonomous mode
- Toggle Storm Watch — turn Storm Watch on or off
- Set battery reserve — change the minimum charge percentage your battery keeps in reserve
- Grid charging — disable or enable Tesla charging your battery from the grid at the moment this automation fires (Scheduled or Adaptive only — see below)
- Hold Powerwall limits — cap grid import, export or battery charging from a start time to an end time (paired Powerwalls, rolling out; see Powerwall limits)
- Any combination of the above in a single automation
When to use it
Section titled “When to use it”Custom Schedule is the right choice when you want something to happen at a fixed time, regardless of your actual energy usage. Examples:
- Switch to self-consumption mode at 4 PM every weekday to maximize battery use during peak hours
- Set battery reserve to 0% at midnight (to allow full discharge overnight)
- Turn Storm Watch off every Monday morning after weekend storm season
- Switch to autonomous mode every Sunday when your solar forecast is uncertain
Creating a Custom Schedule automation
Section titled “Creating a Custom Schedule automation”-
Go to Automations and click + Add Automation
-
Select the Custom Schedule tab
-
Give your automation a name (required)
-
Set the At time — this is when the automation runs each day, in your account timezone
-
Choose what action to take:
- Operational Mode: check this box and choose Self-Powered or Autonomous
- Storm Watch: check this box and choose On or Off
- Battery Reserve: check this box and enter a percentage (0–100%)
You must select at least one action.
-
Set the schedule:
- Choose which days of the week the automation runs (default: Mon–Fri)
- Choose which months it’s active (default: all months)
-
Click Create Automation
Settings reference
Section titled “Settings reference”| Setting | What it does | Default |
|---|---|---|
| Name | Label shown on your automation card | Required |
| Description | Optional note to yourself | Empty |
| At (Trigger Time) | Exact time the automation fires (24-hour format) | 08:00 |
| Until | When Powerwall limits end. Required once a limit is checked (paired Powerwalls) | None |
| Powerwall limits | Grid import (with battery floor), export and battery charging limits held from At until Until (Scheduled or Adaptive, paired Powerwall) | Off |
| Operational Mode | Switches Powerwall mode at trigger time | Off |
| → Self-Powered | Battery-first, minimizes grid draw | — |
| → Autonomous | Tesla manages automatically | — |
| Storm Watch | Enables or disables Storm Watch at trigger time | Off |
| → On | Activates Storm Watch (charges to 100%) | — |
| → Off | Deactivates Storm Watch | — |
| Battery Reserve | Sets the minimum battery reserve % | Off |
| Grid Charging | Disables or enables Tesla charging your battery from the grid when this automation fires (Scheduled or Adaptive required) | Do Nothing |
| → Do Nothing | No effect on grid charging | — |
| → Disable | Stops charging the battery from the grid | — |
| → Enable | Forces charging the battery from the grid | — |
| Days of Week | Which days the automation runs | Mon–Fri |
| Months | Which months the automation is active. Pick at least one | All months |
Operational modes explained
Section titled “Operational modes explained”Self-Powered (Self-Consumption) Your Powerwall prioritizes powering your home from solar and battery before drawing from the grid. When battery is depleted, the system switches to grid power. This mode gives you the most control over when you draw from the grid.
Autonomous Tesla manages your Powerwall automatically based on time-of-use rates, weather forecasts, and usage patterns. Best if you’re on a time-of-use rate plan and want Tesla’s algorithms to optimize for you. Less predictable day-to-day, but often optimal over time.
Storm Watch explained
Section titled “Storm Watch explained”Storm Watch is a Tesla feature that charges your Powerwall to 100% and holds a high reserve when severe weather is forecast in your area. It overrides your normal reserve settings.
This is usually helpful, but can interfere with automations. For example: if Storm Watch activates and charges your battery to 100%, a DemandGuard automation might not be able to discharge it as planned.
A Custom Schedule automation can turn Storm Watch off at a specific time if you want to prevent it from interfering with your energy strategy.
Grid charging explained
Section titled “Grid charging explained”The Grid Charging setting controls whether Tesla is allowed to charge your battery from the grid at the moment this automation fires. Choose one of three options:
- Do Nothing (default) — no change to grid charging
- Disable — stop Tesla from charging your battery from the grid, useful if you’re switching to a mode where you don’t want the battery topping up from the grid at the same time
- Enable — force Tesla to allow charging your battery from the grid, useful when you need to guarantee a top-off (for example, before a trip) regardless of Tesla’s normal charging behavior
This is a one-time setting applied when the automation triggers, not an ongoing window — Custom Schedule automations run a single action at a fixed time, with no “end” the way Peak Time or DemandGuard have one. Because a Custom Schedule automation only fires once, you may want a pair of automations — one to disable grid charging, another later to re-enable it.
This option requires a Scheduled or Adaptive subscription. On the free plan, all three options are visible but disabled, with a tooltip explaining the requirement. That applies in the iPhone and Android apps too. If your plan ends while a rule has a grid charging setting, the rule keeps running but skips that setting, and the Activity Log notes Skipped grid charging — it requires a Scheduled plan or higher.
If you move to the free plan with a rule that has grid charging set, saving it on the web switches the setting to Do Nothing.
Powerwall limits (paired Powerwalls)
Section titled “Powerwall limits (paired Powerwalls)”This section sits under Advanced in the editor. It’s closed unless the rule already has a limit.
Most of a Custom Schedule automation is a single action at a single time. Powerwall limits are the exception: they run over a window. You set At (when the limits start) and Until (when they end), and Grid Getter holds them on your Powerwall in between. Until is required as soon as you check a limit. If it’s earlier than At, the window ends the next day, so 10:00 PM to 6:00 AM works.
There are three limits, and you can use any mix of them.
- Limit grid import. Your battery covers anything above the number you set, even below your reserve, down to a battery floor you also set (5% at the lowest; the editor starts it at your current reserve). A limit of 0 means no grid draw for as long as the battery can cover the house. This one drains the battery on purpose, so pick the floor with care.
- Limit export. When the battery is full, extra solar is turned down instead of exported. A limit of 0 means no export.
- Limit battery charging. Caps how fast the battery charges, from solar or the grid, and never slows discharge. Your Powerwall’s charge-rate setting slows discharge too, so the limit is only on while the battery is charging. When the battery starts discharging, Grid Getter takes the limit off within about a minute, and puts it back when the battery charges again (at the earliest 10 minutes after it came off, so a passing cloud doesn’t flip it back and forth). The Activity Log shows each change.
When the limits end
Section titled “When the limits end”They end at Until. They also end sooner if:
- the battery drops to your floor (import limit only). You get a notification, and the Activity Log says the battery reached the floor and the limit ended early,
- you turn the automation off, change its limits or schedule, or delete it, or
- you pause the site.
Changing a rule’s limits, At, Until, days, months or time zone while its limits are running ends them right then. The new values apply from the next start, not mid-window. Other edits, such as the name, description, operational mode, Storm Watch or reserve, don’t interrupt anything. Creating or turning on a rule in the middle of its window doesn’t start the limits either: they start at the next At. If a limit ever fails to release at Until, a backstop releases it a few minutes later.
There’s one exception, covered in With DemandGuard: while a paired DemandGuard window is open, a limit that ends early can stay on your Powerwall until that window ends.
Stacking
Section titled “Stacking”Two limits of the same kind can overlap. The editor tells you when they do, and the lower limit applies. The same goes for a limit set by another Custom Schedule automation and one set by DemandGuard on your Powerwall.
With DemandGuard
Section titled “With DemandGuard”On a paired Powerwall, if a Custom Schedule import limit is already running when a DemandGuard window starts, the lower of the two applies from the start of the window and holds until the window ends. That’s true even if your limit ends sooner: Until passing, the battery reaching your floor, or you turning the rule off, editing it or deleting it all release your limit, but DemandGuard keeps holding the lower one until its window ends. When Until passes or the battery reaches your floor, the notification and the Activity Log say your limit was released and that DemandGuard is still holding its limit until its window ends. DemandGuard’s own battery floor still applies the whole time, so it won’t drain the battery below that.
A limit that starts during a paired DemandGuard window waits and takes effect when the window ends. Export and charging limits wait too: one that starts, or one that ends, while the window is open changes on your Powerwall when the window ends. A charging limit that’s already on when the window starts stays on until the window ends, even while the battery discharges.
Classic DemandGuard, the version that doesn’t use the paired connection, never touches the grid import limit, so your limits apply and end on their own schedule through it.
With Pre-Peak Charge
Section titled “With Pre-Peak Charge”Pre-Peak Charge plans its top-up around limits that are already in force when it evaluates. An import limit that leaves little room above your house load slows the charge, and if it leaves none, Pre-Peak waits and says why. It doesn’t yet plan for a limit that starts later in the day. If you set one to begin before your peak window, expect Pre-Peak to find out only when it starts.
With Storm Watch
Section titled “With Storm Watch”Storm Watch is Tesla’s feature, and we haven’t been able to confirm whether its grid charging respects your import limit. When a rule includes Storm Watch, the editor warns that it may still charge from the grid up to your limit. Don’t rely on the import limit to stop a storm top-up.
Who can use it
Section titled “Who can use it”- Plan. Scheduled or Adaptive. On the free plan the section shows, locked, with “Available on Scheduled plans and above.” A rule that already has limits when you drop to free keeps them stored but stops applying them, and the editor offers Remove Powerwall limits.
- Powerwall. It has to be paired. On an unpaired Powerwall every box is disabled and the section says “Requires a paired Powerwall”, with a Pair now link. If your Powerwall’s firmware hasn’t been verified yet, the section says so and stays locked. In either state the web editor won’t let you add or change limits. Limits you already saved stay saved, but they won’t start until the Powerwall is paired and verified.
In the Activity Log
Section titled “In the Activity Log”The Activity Log records the limits starting (for example, Grid import ≤ 3.0 kW until 9:00 PM requested on your Powerwall), a limit that couldn’t be set and why, and a limit ended early by the floor. When a window ends and releases at least one limit, you get a notification saying so. The rule’s card on the Automations page shows a one-line summary, such as 6:00 PM–9:00 PM · Grid import ≤ 3 kW · Export ≤ 0 kW.
Mode change verification
Section titled “Mode change verification”When a Custom Schedule automation changes your Powerwall’s operating mode, Grid Getter doesn’t just take Tesla’s word for it. A couple of minutes after the change (Powerwalls can take a little while to switch), Grid Getter checks your system’s reported mode. If it hasn’t switched, the change is sent once more and checked again. Only if your Powerwall still hasn’t switched after that second attempt do we mark the run as failed — you’ll get a notification and an activity-log entry telling you which mode the system is stuck in, instead of a success message for a change that never happened.
A successful verification is silent — you only hear about it when something’s wrong.
If the check finds your system in a different mode and re-applies the automation’s mode, that gets its own activity-log entry. This matters if you change the mode yourself in the Tesla app shortly after an automation runs: the automation will set it back, and the activity log will show exactly when and why. If you want a manual change to stick, disable the automation (or adjust its schedule) rather than racing it.
During a DemandGuard window
Section titled “During a DemandGuard window”A Custom Schedule automation can fire while one of your DemandGuard windows is running. DemandGuard is managing your Powerwall’s operating mode, battery reserve and grid charging for its whole window, so the automation leaves those three alone and still runs its other actions, such as Storm Watch. Your Activity Log shows what it skipped, for example: “Skipped operational mode, battery reserve, and grid charging — DemandGuard is managing the battery right now.”
If you want one of those changes to happen, schedule it after the DemandGuard window ends. A reserve change made inside the window doesn’t need to wait, though: change it yourself and DemandGuard restores your new value when the window closes.
The mode check described above stands down the same way. If a DemandGuard window has started by the time it checks, a different mode is DemandGuard’s doing, so it isn’t re-applied or reported as a failure.
During a pause
Section titled “During a pause”A pause skips Custom Schedule automations on every paused day. Your rule stays on and unedited. If its time passes during the pause, it doesn’t fire late when you tap Resume. It waits for its next scheduled run.
Schedule overlap restriction
Section titled “Schedule overlap restriction”Two active Custom Schedule automations can’t be set to fire at the same time on overlapping days and months. If you try to save one that conflicts with another active automation, Grid Getter blocks the save and shows an error pointing to the conflict.
Disabled automations are ignored — you can keep older variants (say, a “summer” version) saved but turned off, and create a new one in the same time slot. Toggle the off-season one back on whenever you’re ready to switch.
To fix a conflict between two active automations, change the trigger time, adjust the days/months so they no longer share a slot, or disable the one you’re not using.
Plan limits
Section titled “Plan limits”- Free plan: One active Custom Schedule automation at a time. You can have more created — just enable/disable them as needed.
- Scheduled / Adaptive: Unlimited active automations.
See Subscription Tiers for details.